View Issue Details
ID | Project | Category | Date Submitted | Last Update | |
---|---|---|---|---|---|
0012175 | Bionic Dues | Bug - Gameplay | Sep 8, 2013 5:59 pm | Sep 11, 2013 6:07 pm | |
Reporter | orzelek | Assigned To | keith.lamothe | ||
Status | resolved | Resolution | fixed | ||
Fixed in Version | 0.908 | ||||
Summary | 0012175: Power generated by parts in same system bonus doesn't work | ||||
Description | Magnetic containment chamber placed next to slave reactor in reactor systems doesn't affect overall bot power correctly. Proper value of generation is shown when you are inside Reactor system on the system information. It changes when containment chamber is added. But there is no effect on global power for bot. | ||||
Tags | No tags attached. | ||||
Internal Weight | New | ||||
|
For 0.908: * The "+% to power generated by parts in the same system" effect (which is featured most prominently on the Magnetic Containment Chamber part-type), has been changed to "+% Total Power Generation", with the following new description: ** "Increases all power generated by this exo (including the reactor's base amount, and any power-generating parts installed in any system)." ** Also fixed a bug where this % wasn't even being fully factored in for power generation by parts in the same system. ** This may result in an overall effect that's just too nice to the player. Our kindly players would _surely_ inform us of such an intolerable discrepancy, right? Thanks :) |
Date Modified | Username | Field | Change |
---|---|---|---|
Sep 8, 2013 5:59 pm | orzelek | New Issue | |
Sep 11, 2013 6:07 pm | keith.lamothe | Internal Weight | => New |
Sep 11, 2013 6:07 pm | keith.lamothe | Note Added: 0033500 | |
Sep 11, 2013 6:07 pm | keith.lamothe | Status | new => resolved |
Sep 11, 2013 6:07 pm | keith.lamothe | Fixed in Version | => 0.908 |
Sep 11, 2013 6:07 pm | keith.lamothe | Resolution | open => fixed |
Sep 11, 2013 6:07 pm | keith.lamothe | Assigned To | => keith.lamothe |