View Issue Details

IDProjectCategoryLast Update
0012175Bionic DuesBug - GameplaySep 11, 2013 6:07 pm
Reporterorzelek Assigned Tokeith.lamothe  
Status resolvedResolutionfixed 
Fixed in Version0.908 
Summary0012175: Power generated by parts in same system bonus doesn't work
DescriptionMagnetic containment chamber placed next to slave reactor in reactor systems doesn't affect overall bot power correctly.
Proper value of generation is shown when you are inside Reactor system on the system information. It changes when containment chamber is added. But there is no effect on global power for bot.
TagsNo tags attached.
Internal WeightNew

Activities

keith.lamothe

Sep 11, 2013 6:07 pm

administrator   ~0033500

For 0.908:

* The "+% to power generated by parts in the same system" effect (which is featured most prominently on the Magnetic Containment Chamber part-type), has been changed to "+% Total Power Generation", with the following new description:
** "Increases all power generated by this exo (including the reactor's base amount, and any power-generating parts installed in any system)."
** Also fixed a bug where this % wasn't even being fully factored in for power generation by parts in the same system.
** This may result in an overall effect that's just too nice to the player. Our kindly players would _surely_ inform us of such an intolerable discrepancy, right?

Thanks :)

Issue History

Date Modified Username Field Change
Sep 8, 2013 5:59 pm orzelek New Issue
Sep 11, 2013 6:07 pm keith.lamothe Internal Weight => New
Sep 11, 2013 6:07 pm keith.lamothe Note Added: 0033500
Sep 11, 2013 6:07 pm keith.lamothe Status new => resolved
Sep 11, 2013 6:07 pm keith.lamothe Fixed in Version => 0.908
Sep 11, 2013 6:07 pm keith.lamothe Resolution open => fixed
Sep 11, 2013 6:07 pm keith.lamothe Assigned To => keith.lamothe